您好, 欢迎来到化工仪器网

| 注册| 产品展厅| 收藏该商铺

18217040487

products

目录:TA仪器>>导热仪>> FOX 801导热仪 FOX 801

导热仪 FOX 801
  • 导热仪 FOX 801
参考价 面议
具体成交价以合同协议为准
参考价 面议
具体成交价以合同协议为准
  • 品牌 TA/美国
  • 型号 FOX 801
  • 厂商性质 生产商
  • 产品资料 下载
  • 所在地 上海市
属性

>

更新时间:2024-01-26 10:27:56浏览次数:2177评价

联系我们时请说明是化工仪器网上看到的信息,谢谢!

同类优质产品

更多产品
导热仪FOX 801可在复杂的数字温度控制算法监测板温度每秒20倍和快速带来系统选择的平衡测试条件。可以多次执行测试,用户选择在一个温度或温度高达-15°C到85°C。测试结果可以输出到主机。
导热仪FOX 801介绍
比较有意义的热导率测量是进行样品与维度代表真实世界的条件。这些维度,如样本厚度宽度比。往往要求的国际标准。狐狸系列的四个模型热流米适应广泛的样品尺寸。每个仪器都有小尺寸样品测试的灵活性和超大号的样品可以测试开放的配置不牺牲测量精度和准确性。

The most meaningful thermal conductivity measurements are performed on samples with dimensions representative of real world conditions. These dimensions, such as sample thickness to width ratio, are requirements often outlined by international standards. Four models of the FOX Series Heat Flow Meters accommodate the widest range of sample dimensions. Each instrument has the flexibility to test samples with smaller dimensions and oversized samples can be tested in the open-door configuration without sacrificing measurement precision and accuracy.

Conforms to ASTM C 518 & ISO 8301

Specimen size 762 mm sq. (30”)

Thickness Range from 0 to 305 mm (12”)

Compact size

Accuracy better than 1%

Easy to use, rapid operation

Microprocessor based

Stand alone operation

Solid state cooling\heating

Operation from –15°C to 85°C (plate)

Digital Thickness readout to 0.001”

Powerful 24 Bit A/D Converter

Two Thin-Film Heat Flux Transducers

Temperature Control to 0.01°C

Two Zone Heating/Cooling in Plates

Ideal for fiberglass insulation testing

Years ahead of competition

Full One Year Parts and Labor Warranty

Suitable for R&D and QC testing

Win_Therm Software extends flexibility

Extremely energy efficient

Simplicity of use:

Place the specimen in the test chamber, close the door and answer several prompts displayed on a clear 4 line alphanumeric LCD display. The Instrument does the rest.

The plate spacing is adjusted automatically to the desired specimen thickness (accurate to +\-0.001”).

The sophisticated digital temperature control algorithm monitors the plate temperatures 20 times per second and rapidly brings the system to the selected equilibrium test condition. Tests can be performed repeatedly at one temperature or at up to 9 user selected temperatures between –15°C and 85°C. The test results can be output to the host computer.

会员登录

请输入账号

请输入密码

=

请输验证码

收藏该商铺

标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

您的留言已提交成功!我们将在第一时间回复您~
在线留言

会员登录

请输入账号

请输入密码

=

请输验证码

收藏该商铺

该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:
热线电话 在线询价