进口/排气口:G2
表格如下:
型号 | 标准抽速m3/h | 抽速 m3/h | 关气镇阀极限压强 mbar | 开气镇阀极限压强mbar | 噪音db | 注油量L | 电机转速/min | 电机功率(KW) | 防护等级(IP) |
SV10 | 11 | 9.5 | ≤1 | ≤2 | 60 | 0.5 | 3000 | 0.55 | 0.55-F |
SV16B | 16 | 15 | ≤1 | ≤2 | 60 | 0.5 | 3000 | 0.55 | 0.55-F |
SV25B | 26 | 22.5 | ≤0.5 | ≤0.8 | 64 | 0.5 | 3000 | 0.9 | 0.55-F |
SV40B | 44 | 38.5 | ≤0.5 | ≤1.5 | 60 | 1 | 1500 | 1.1 | 0.55-F |
SV65B | 59 | 54 | ≤0.5 | ≤1.5 | 60 | 2 | 1500 | 1.5 | 0.55-F |
SV100B | 97.5 | 87.5 | ≤0.5 | ≤1.5 | 61 | 2 | 1500 | 2.2 | 0.55-F |
SV200 | 180 | 170 | ≤0.08 | ≤0.7 | 69 | 5 | 1450 | 4 | 55 |
SV300 | 280 | 240 | ≤0.08 | ≤1 | 70 | 8.5 | 1450 | 5.5 | 55 |
SV500 | 570 | 510 | ≤0.08 | ≤0.7 | 71 | 35 | 1500 | 11 | 54-F |
SV630 | 700 | 640 | ≤0.08 | ≤0.7 | 75 | 35 | 1500 | 15 | 54-F |
SV630F | 700 | 640 | ≤0.08 | ≤0.7 | 75 | 35 | 1500 | 15 | 54-F |
SV750 | 840 | 755 | ≤0.08 | ≤0.7 | 78 | 35 | 1500 | 18.5 | 54-F |
SV1200 | 1150 | 1070 | ≤0.1 | ≤1.5 | 75 | 60 | 1460 | 22 | 54 |
真空泵不能启动:主要表现为真空泵加电后不能启动运转。这时应首先检查真空泵的电路部分,如保险管是否烧毁、电路部分有没有元气件烧坏。在排除电路部分的故障后,应考虑以下两个因素:
(1)电机烧坏。主要为电机定子线圈烧毁,引起原因较多,如瞬间电流过大,电机轴承使用久了被磨损,致使轴承摩擦阻力变大,电机功率加大,引起温度上升,烧毁电机。这时应先检查电机轴承,再检查电机线圈。轴承损坏就更换轴承;电机线圈烧毁则应维修电机,重新绕制定子线圈。轴承和线圈损坏严重时,就需更换电机了。
(2)旋片卡阻。主要表现为旋片与泵腔内表面的摩擦阻力过大,致使电机无法带动旋片。原因是旋片变形,转子内的弹簧张开后不能复位,或弹簧压力和旋片自身离心力的合力过大,导致旋片与泵腔内表面的摩擦阻力过大。这时就应及时修复旋片和弹簧,若不能修复则应更换。
工作过程中出口无压力或压力低泵工作时,出口无压力或压力低的原因很多。但都不会在较短的运行时间内出现故障。根据以前检修时发现,出口排气阀损坏严重,推断是这个原因造成的。排气阀的阀片是一块1—1.5厚的铁板,很容易被腐蚀。
真空泵漏油:这是旋片式机械真空泵的故障之一,主要发生在真空泵的油窗、油箱密封垫、电机轴承轴封三个位置上,其主要原因是真空泵使用时间过长而引起这些部位老化,密封失效,从而导致漏油。