The TC20 automated cell counter counts mammalian cells in one simple step using its innovative auto-focus technology and sophisticated cell counting algorithm to produce accurate cell counts in less than 30 seconds. Upon insertion of a counting slide, the TC20 cell counter rapidly provides a total cell count (with or without trypan blue staining) and assesses cell viability via trypan blue exclusion.

Key Features and Benefits

·         Compatible with a broad range of cell sizes and types — counts cell lines, primary cells (from tissue or blood), and stem cells

·         Innovative auto-focus technology — removes the variation associated with manual focusing and leads to precise cell counts in 30 seconds

·         Cell size gates — user selects a population of interest in complex samples, such as primary cells, or lets the cell counting algorithm do all the work

·         Cell viability — analyzes cells accuray using multifocal plane analysis

·         Easy to archive and analyze — stores up to 100 counts in the onboard memory for access any time, or use the optional TC20 data analyzer software on your PC to further analyze exported cell images

Getting all the data you need about your cell cultures is fast and easy; the TC20 cell counter and disposable counting slides eliminate the need for tedious setup, cleaning, or maintenance. The TC20 cell counter is simple and intuitive to use 

Get Accurate and Reproducible Results

The TC20 automated cell counter uses microscopy with auto-focus that analyzes multiple focal planes to identify the best plane. Without requiring any user input, the sophisticated cell counting algorithm uses the image acquired from the best focal plane to identify cells and exclude debris, thereby calculating the total cell count. The auto-focus leads to highly reproducible cell counts with reduced user-to-user variability compared to a hemocytometer and cell counters with manual focus. Using auto-focus instead of subjective manual focusing is especially important when assessing cell viability because an incorrectly selected focal plane will lead to inaccurate results.

Unlike cell counters based on electrical impedance (Coulter principle), the TC20 image-based analysis allows the user to view the cells in real time, providing visual proof that the TC20 cell counter has correctly identified cells.

The TC20 automated cell counter provides accuracy comparable to results obtained with a hemocytometer. It can count cells with a 6–50 μm cell diameter and within a broad concentration range of 5 x 104–1 x 107cells/ml, which eliminates the need to dilute cells, thus reducing errors associated with sample dilutions prior to counting.

The counter uses disposable counting slides with a patent-pending design that ensures even distribution of cells throughout the counting chamber, regardless of the user's pipetting style, leading to accurate and consistent cell counts.

For complex samples composed of multiple cell populations, such as primary cells, users can adjust the cell size gates to define the population of interest that will be counted. When counting multiple sample replicates, the TC20 cell counter can save the position of the cell size gates and apply them to subsequent counts.

 

Cell Viability

The TC20 cell counter uses multifocal plane analysis to assess cell viability. The conventional method of analyzing viability using a single focal plane can lead to inaccurate conclusions because light scattering and the alignment of cells at different heights in a counting chamber can change the appearance of cells — live cells may appear to be dead and vice versa. To determine if cells are viable, the TC20 counter analyzes each cell using images acquired from multiple focal planes during the focusing step.

Minimize Your Sample Preparation

The broad concentration range of the TC20 cell counter eliminates the need to dilute cells prior to counting, reducing the errors associated with sample dilutions that may be necessary when counting cells by other methods. The counting algorithm discriminates and counts individual cells within clusters of up to five cells, providing accurate counts without the need to extensively declump cells prior to loading.

 

 

Counting time, sec

30

Cell concentration range, cells/ml

5 x 104–1 x 107

Optimal cell concentration range, cells/ml

1 x 105–5 x 106

Cell diameter range, µm

6–50

Sample volume, µl

10

Data storage, counts

100

Data export

Via USB flash drive

Printer connectivity

Yes

Dilution calculator

Yes

Image of cells available

Yes

Dimensions (W x D x H), cm (in)

19 x 15 x 25.4 (7.5 x 6 x 10)

Weight without the external power supply, kg (lb)

2.2 (4.8)

    
留言框
感兴趣的产品: *
留言内容:
您的姓名: *
您的单位:
联系电话: *
微信:
常用邮箱:
详细地址:
省份: *
验证码: * =   请输入计算结果(填写阿拉伯数字),如:三加四=7
      
产品搜索

请输入产品关键字:

联系方式
地址:上海市浦东新区锦绣东路412弄28号
邮编:200135
联系人:仪器部江朋
电话:86-021-51619380
传真:86-021-61924370
手机:13918425787
留言:发送留言
个性化:www.aybio3517.com
网址:www.aybio3517.com
商铺:https://www.chem17.com/st175454/
| 商铺首页 | 公司档案 | 产品展示 | 供应信息 | 公司动态 | 询价留言 | 联系我们 | 会员管理 |
化工仪器网 设计制作,未经允许翻录必究.Copyright(C) https://www.chem17.com, All rights reserved.
以上信息由企业自行提供,信息内容的真实性、准确性和合法性由相关企业负责,化工仪器网对此不承担任何保证责任。
温馨提示:为规避购买风险,建议您在购买产品前务必确认供应商资质及产品质量。
二维码 在线交流

扫一扫访问手机站