产品推荐:气相|液相|光谱|质谱|电化学|元素分析|水分测定仪|样品前处理|试验机|培养箱


化工仪器网>技术中心>专业论文>正文

欢迎联系我

有什么可以帮您? 在线咨询

人白介素2(IL-2)试剂盒说明书

来源:上海恒远生物科技有限公司   2011年09月09日 12:07  

RD

 
Human Interleukin 2 (IL-2)

FOR RESEARCH USE ONLY

Assay range30 pg/ml -1200 pg/ml                   96 determinations

Purpose

This kit allows for the determination of IL-2 concentrations in Human serum, cell culture supernates and other biological fluids

 

Principle of the assay

The kit assay Human Interleukin 2 (IL-2) level in the sampleuse Purified Human Interleukin 2 (IL-2)antibody to coat microtiter plate wells, make solid-phase antibody, then add Interleukin 2(IL-2) to wells, Combined antibody which With HRP labeled goat anti- Human become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of  Human Interleukin 2 (IL-2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Materials provided with the kit

1

wash  solution

20ml×1bottle

7

Stopp Solution

6ml×1 bottle

2

HRP-Conjugate reagent

6ml×1 bottle

8

Standard2400pg/ml

0.5ml×1 bottle

3

Microelisa stripplate

12well×8strips

9

Standard diluent

1.5ml×1bottle

4

Sample diluent

6ml×1 bottle

10

Instruction

1

5

Chromogen Solution A

6ml×1 bottle

11

Closure plate membrane

2

6

Chromogen Solution B

6ml×1 bottle

12

Sealed bags

1

Specimen requirements

1.       extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 to preserve, Avoid repeated freeze-thaw cycles.

2.       Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

Assay procedure

1.       Dilute and add sample:Dilute Original density Standard as follow table:

1200 pg/ml

5 Standard

150μl Original density Standard+150μl Standard diluent

600 pg/ml

4 Standard

150μl 5 Standard+150μl Standard diluent

300 pg/ml

3 Standard

150μl 4 Standard+150μl Standard diluent

150 pg/ml

2 Standard

150μl 3 Standard +150μl Standard diluent

75 pg/ml

1 Standard

150μl 2 Standard +150μl Standard diluent

2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37.

4.Configurate liquid: 30-fold wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.

5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

6.add enzymeAdd HRP-Conjugate reagent 50μl to each well, except  blank well.

7.incubateOperation with 3.

8.washingOperation with 5.

9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37

10.Stop the reactionAdd Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).

11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.

Steps description

Standard, Sample diluent

 

Add Standard, Sample diluent, incubate for 30 min at 37.

 

Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

 

Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37.

 

Add Stopp Solution

 

Read absorbance at 450nm within 15 min

 

calculate

Calculate

Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.

Important notes

1.       The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

2.       washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

3.       add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

4.       if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

5.       Closure plate membrane only limits the disposable use, to avoid cross-contamination.

6.       The substrate evade the light preservation.

7.       Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

8.       All samples, washing buffer and each kind of reject should according to infective material process.

9.       Do not mix reagents with those from other lots.

 

Storage and validity

1Storage  2-8.

2validity six months.

 

免责声明

  • 凡本网注明“来源:化工仪器网”的所有作品,均为浙江兴旺宝明通网络有限公司-化工仪器网合法拥有版权或有权使用的作品,未经本网授权不得转载、摘编或利用其它方式使用上述作品。已经本网授权使用作品的,应在授权范围内使用,并注明“来源:化工仪器网”。违反上述声明者,本网将追究其相关法律责任。
  • 本网转载并注明自其他来源(非化工仪器网)的作品,目的在于传递更多信息,并不代表本网赞同其观点和对其真实性负责,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品第一来源,并自负版权等法律责任。
  • 如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。
企业未开通此功能
详询客服 : 0571-87858618