产品推荐:气相|液相|光谱|质谱|电化学|元素分析|水分测定仪|样品前处理|试验机|培养箱


化工仪器网>技术中心>其他文章>正文

欢迎联系我

有什么可以帮您? 在线咨询

Schneider驱动器LTMR100CFM数据

来源:上海萨起工业控制设备有限公司   2023年09月15日 10:52  

Schneider 驱动器LTMR100CFM

TeSys T是一种电机管理系统,当与短路保护和接触器一起使用时,它提供完整的电机监控、控制和保护。它管理最关键的流程,同时减少停机时间,提高生产力,并预测流程中会发生什么,因为它可以在大范围内准确监测电流、电压和功率。该电机管理系统也是一个灵活的系统,支持六种通信协议,即Modbus™, CANopen,DeviceNet™, Profibus™, 以太网/IP和Modbus/TCP。TeSys T电机管理系统由几个组件组成,包括LTMR控制器、扩展模块、HMI和软件以及几个附件。LTMR控制器是管理基本功能的系统的主要组件。这包括对接地电流、电机温度、电机三相电流的测量,控制器还包括用于故障管理的逻辑输入和输出

Main
RangeTeSys
Product nameTeSys T
device short nameLTMR
Product or component typeMotor controller
Device applicationEquipment monitoring and control
Measurement current5…100 A
[Us] rated supply voltage100...240 V AC 50/60 Hz
Current consumption8...62.8 mA
Supply voltage limits93.5…264 V AC
Communication port protocolCANopen
Bus typeCANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, SUB-D 9 with 4 twisted shielded pairs cable
CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, terminal block with 4 twisted shielded pairs cable

Complementary
[Ui] rated insulation voltage690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
[Uimp] rated impulse withstand voltage4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
Short-circuit withstand100 kA conforming to EN/IEC 60947-4-1
Associated fuse rating4 A gG for output
0.5 A gG for control circuit
Protection typeThermal protection
Locked rotor
Phase failure
Earth-leakage protection
Overload (long time)
Power factor variation
Phase unbalance
Load fluctuation
Thermal overload protection
Reverse polarity protection
Overload
Network and machine diagnosis typeEvent recording
Trip history information
Starting current and time
Running hours counter/operating time
Motor control command recording
Remaining operating time before overload tripping
Fault recording
Phase fault and earth fault trip counters
Waiting time after overload tripping
Trip context information
Logic input number6
Input current3.1 mA at 100 V
7.5 mA at 240 V
Current state 0 guaranteedLogic input: 0...40 V and <= 15 mA for 25 ms
Current state 1 guaranteedLogic input: 79...264 V and >= 2 mA for 25 ms
maximum output switching frequency2 Hz
Load current5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
Permissible power480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
maximum operating rate1800 cyc/h
Contacts type and composition1 NO + 1 NC fault signal
3 NO
Metering typeEarth-fault current
Phase current I1, I2, I3 RMS
Imbalance current
Temperature
Average current Iavg
Measurement accuracy5...15 % earth fault current internal measurement
1 % voltage (100...830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
5 % active and reactive power
0,02 current
Overvoltage categoryIII
Connection pitch5.08 mm




免责声明

  • 凡本网注明“来源:化工仪器网”的所有作品,均为浙江兴旺宝明通网络有限公司-化工仪器网合法拥有版权或有权使用的作品,未经本网授权不得转载、摘编或利用其它方式使用上述作品。已经本网授权使用作品的,应在授权范围内使用,并注明“来源:化工仪器网”。违反上述声明者,本网将追究其相关法律责任。
  • 本网转载并注明自其他来源(非化工仪器网)的作品,目的在于传递更多信息,并不代表本网赞同其观点和对其真实性负责,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品第一来源,并自负版权等法律责任。
  • 如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。
企业未开通此功能
详询客服 : 0571-87858618