深圳市鑫博恒业科技有限公司

示温贴纸,英国测温试纸,omega插头,k型感温线

化工仪器网收藏该商铺

18

联系电话

13823144468

您所在位置:
深圳市鑫博恒业科技有限公司>>美国omega热电阻>> PR-21SL-3-100-A-1500-M12-1热电阻 美国omega热电阻
 QQ交谈
产品展示

PR-21SL-3-100-A-1500-M12-1热电阻 美国omega热电阻

  • 公司名称:
  • 更新时间:
  • 所 在 地:
  • 生产地址:
  • 浏览次数:
  • 深圳市鑫博恒业科技有限公司
  • 2024-03-30 12:35:34
  • 深圳市
  • 美国omega
  • 967

我要询价

【简单介绍】

PR-21SL-3-100-A-1500-M12-1热电阻 美国omega热电阻,美国omega热电阻温度传感器 一手货源,优势批发

【详细说明】


 PR-21SL-3-100-A-1500-M12-1热电阻 美国omega热电阻

压簧压RTD传感器,带M12连接器
PR-21SL-M12 Series
新产品!
簧压RTD传感器,带M12连接器
PR-21SL-M12 Series:簧压RTD传感器,带M12连接器
PR-21SL-3-100-A-0600-M12-1
M12 Connectors for Easy Assembly, No Tools Required. An M12 Extension Cable is Required for Installation.
Spring Loaded RTD Probes for Use in Thermowells, Insures Proper Tip Contact with Thermowell and Maximum Performance
4-Wire Class A PT100 RTDs, Can Be Used in Any 2, 3 or 4-Wire Application for Maximum Flexibility
Fits All Standard 0.260" Bore Thermowells (Note: Thermowell Not Included)
Probe Length = Thermowell Stem Length for Easy Selection (See Figure Below)
Adjustable Self Gripping Spring Allows For Use in Shorter Thermowells
Vibration Resistant to 10gs, 10-500Hz (MIL-STD-202G, Method 204D, Condition A) for 6" Length and Shorter
Can Be Combined With a Selection of Programmable and Fixed Range Transmitters
Note: These Sensors Require an M12 Extension Cable to Connect the Sensor To Your Instrumentation. A Partial List Of Our M12 Extension Cables is Included in the Ordering Table Below.
The Series PR-21SL Spring Loaded RTD has been designed to provide our customers with a simple, effective way to adapt our M12 enabled RTD probes for use in thermowells. To insure the best possible performance,

 

the PR-21SL RTD has a spring loading feature that maintains contact between the probe and thermowell under static and vibration conditions. This helps to maintain heat transfer between the thermowell and probe, as well as
 

dampening the effect of vibration on the sensor. With a demonstrated ability to withstand 10gs of vibration between 10 and 500HZ (for 6" long and shorter probes per MIL-STD-202G, Method 204D, Test Condition A), this probe has shown its ability to withstand real-world conditions.
To select the right length probe for your application, simply measure the depth of the bore in the thermowell (the length from the top of the thermowell to the bottom of the bore as shown as the “Thermowell Stem Length” in the sketch below).
The PR-21SL sensor assembly is designed to fit into a thermowell with a stem length equal to that specified in the model number. Simply slide the sensor assembly into the thermowell until bottomed and then compress the spring while
 

making the 1/2NPT connection. Thread sealant tape or thread compound may be used on the 1/2NPT mounting thread to insure easy removal at a later time. The position of the self-gripping spring can also be adjusted so that the sensor
 

can be used in a shorter thermowell, simply twist the spring while sliding it along the probe stem until the needed position is reached.
The PR-21SL can also be used as a back-up sensor for a variety of applications. The spring loading feature can be adjusted to fit a variety of thermowells. The spring loading fitting can be removed altogether and replaced with a compression
 

type fitting if a fixed mounting is needed. The probe (less spring and hex fitting) can also be used with one of Omega's M12-Handle accessories to turn your spring loaded probe into a hand-held probe. This flexibility in mounting options, as
 

well as the simplified and robust connection provided by the M12 connector, makes the PR-21SL the perfect solution for a wide variety of applications.
 


These RTD sensors can be used in any 2, 3 or 4-wire application by selecting one of the two available wiring arrangements (see the wiring diagrams below) and using only those wires needed for your connection. This allows for simplified,
 

trouble free installation with any existing application. This also allows the PR-21 series sensor to be used for a wide variety of replacement applications since it can be connected as-is with just about any measurement or control equipment available.
When ordering your PR-21SL sensor, don't forget your extension cable. Omega offers a wide selection of extension cables including over molded PVC, LCP/PFA, Polyurethane and Silicone cables, as well as customized cables in a variety of

 

cable materials with optional stainless steel braid or hose for improved mechanical protection. Omega also offers a selection of programmable and fixed range transmitters fitted with M12 connections, and a wide selection of controllers, panel meters and other instruments to complete your measurement needs.
Specifications:
Metal Parts: 316L Stainless Steel Sheath and Housing.
Connector: 4-Pin "A"-Coded M12 Plug Connector.
Standard Probe Diameter: 1/4"
Standard Probe Lengths: See Thermowell Stem Lengths in The Order Table Below.
Sensor: Pt100 (100 Ohms at 0°C, .00385 TCR (alpha)) Standard, Pt1000 and Other Options Available.
Accuracy: Class A Standard (per IEC 60751), Others Available Upon Request.
Temperature Range: -50 to 250°C Except for the Connector Which is 85°C Max.
Insulation Resistance: 100 Megohms Minimum at 100VDC at Room Ambient Temperature.
Vibration Resistance: 10gs from 10-500Hz per MIL-STD-202G, Method 204D, Test Condition A.
 

产品型号/产品描述


PR-21SL-3-100-A-0250-M12-1  Spring Loaded RTD Sensor to Fit Thermowells with a Stem Length of 2.5" or Less.
PR-21SL-3-100-A-0400-M12-1 Spring Loaded RTD Sensor to Fit Thermowells with a Stem Length of 4" or Less.
PR-21SL-3-100-A-0600-M12-1 Spring Loaded RTD Sensor to Fit Thermowells with a Stem Length of 6" or Less.
PR-21SL-3-100-A-0900-M12-1 Spring Loaded RTD Sensor to Fit Thermowells with a Stem Length of 9" or Less.
PR-21SL-3-100-A-1200-M12-1 Spring Loaded RTD Sensor to Fit Thermowells with a Stem Length of 12" or Less.
PR-21SL-3-100-A-1500-M12-1 Spring Loaded RTD Sensor to Fit Thermowells with a Stem Length of 15" or Less.
PR-21SL-3-100-A-1800-M12-1 Spring Loaded RTD Sensor to Fit Thermowells with a Stem Length of 18" or Less.
PR-21SL-3-100-A-2400-M12-1 Spring Loaded RTD Sensor to Fit Thermowells with a Stem Length of 24" or Less.
Accessories
M12C-PVC-4-S-F-5 M12 Extension Cable, 4 Wire PVC Cable, Straight Socket Connector One End and Flying Leads the Other, 5 meters long
M12C-PVC-4-R-F-5  M12 Extension Cable, 4 Wire PVC Cable, Right Angled Socket Connector One End and Flying Leads the Other, 5 meters long
M12C-PUR-4-S-F-2  M12 Extension Cable, 4 Wire Polyurethane Cable, Straight Socket Connector One End and Flying Leads the Other, 2 meters long
M12C-PUR-4-S-F-5  M12 Extension Cable, 4 Wire Polyurethane Cable, Straight Socket Connector One End and Flying Leads the Other, 5 meters long
M12C-PUR-4-R-F-5  M12 Extension Cable, 4 Wire Polyurethane Cable, Right Angled Socket Connector One End and Flying Leads the Other, 5 meters long
1/2-260S-U21/2-304SS  304SS Thermowell, 1/2NPT Mounting Thread, Stem Length 4"
1/2-260S-U41/2-304SS  304SS Thermowell, 1/2NPT Mounting Thread, Stem Length 6"
1/2-260S-U71/2-304SS  304SS Thermowell, 1/2NPT Mounting Thread, Stem Length 9"
1/2-260S-U101/2-304SS  304SS Thermowell, 1/2NPT Mounting Thread, Stem Length 12"

 

产品型号说明
(1) (2)
PR-21SL-3-100-A
-M12
选项描述
(1) Length
选择
-0250 代表 2 1/2in. Stem Length
-0400 代表 4in. Stem Length
-0600 代表 6in. Stem Length
-0900 代表 9in. Stem Length
-1200 代表 12in. Stem Length
-1500 代表 15in. Stem Length
-1800 代表 18in. Stem Length
-2400 代表 24in. Stem Length
(2) Wiring Orientation
选择
-1 代表 Standard Wiring (See Diagram)
-2 代表 Optional Wiring (See Diagram)

  PR-21SL-3-100-A-1500-M12-1热电阻 美国omega热电阻

    
留言框
感兴趣的产品: *
留言内容:
您的姓名: *
您的单位:
联系电话: *
微信:
常用邮箱:
详细地址:
省份: *
验证码: * =   请输入计算结果(填写阿拉伯数字),如:三加四=7
      

相关产品

产品搜索

请输入产品关键字:

联系方式
地址:深圳市福田区华强北路华强广场A栋17A(华强北地铁站-A口)
邮编:518031
联系人:赵先华
电话:0755-82768776,82736276
传真:0755-83041664
手机:13823144468
留言:发送留言
个性化:www.xbtes.com
网址:www.xb5j.com
商铺:https://www.chem17.com/st98310/
| 商铺首页 | 公司档案 | 产品展示 | 供应信息 | 公司动态 | 询价留言 | 联系我们 | 会员管理 |
化工仪器网 设计制作,未经允许翻录必究.Copyright(C) https://www.chem17.com, All rights reserved.
以上信息由企业自行提供,信息内容的真实性、准确性和合法性由相关企业负责,化工仪器网对此不承担任何保证责任。
温馨提示:为规避购买风险,建议您在购买产品前务必确认供应商资质及产品质量。
二维码 在线交流

扫一扫访问手机站