2028No supply voltage at the device设备无电源电压.上海仰光电子科技有限公司专业从事各品牌伺服驱动器维修,伺服电机维修,触摸屏维修,变频器维修,伺服器维修,伺服控制器维修,数控系统维修改造,机器人维修保养以及各种板卡,芯片级维修维护,免费检测,快速维修,部分立等可取!

 

包米勒驱动器电机维修必看:

In state transition from "Power-on Disable" to "Ready to Start", a

three-phase supply is to be expected of the active mains rectifier on

its terminals after closing the contact "Ready for Main Contactor

ON" (X2-9; X2-10). 从“电源开启-禁用"到“准备启动"的状态转换三相电源应为有源主整流器闭合触点“准备主接触器"后的端子ON"(X2-9X2-10)。

 

This error is triggered, if no three-phase supply is detected after closing the contact "Ready for Contactor ON" for 5 seconds.

如果在闭合触点“接触器接通准备就绪"5秒钟后未检测到三相电源,则会触发此错误。

 

This error cannot be cleared by the user.

用户无法清除此错误。

This error is reset by the device, if a three-phase supply is detected at the terminals of the active mains rectifier unit.

如果在有源主整流器单元的端子处检测到三相电源,则该错误将由设备重置。

 