| 注册| 产品展厅| 收藏该商铺

行业产品

当前位置:
瑞轩电子科技(上海)有限公司>>DAYTRONIC>>200serise>> model 2140M0ODEL2140计数器

M0ODEL2140计数器

返回列表页
  • M0ODEL2140计数器
收藏
举报
参考价 面议
具体成交价以合同协议为准
  • 型号 model 2140
  • 品牌
  • 厂商性质 经销商
  • 所在地 上海市
在线询价 收藏产品

更新时间:2017-09-18 12:50:57浏览次数:415

联系我们时请说明是化工仪器网上看到的信息,谢谢!

同类优质产品

更多产品

产品简介

产地类别 进口
This extraordinarily versatile dual-channel Counter Meter can perform a wide variety of functions, particularly when it is equipped with the “R“ OPTION (“EXTENDED DUAL-CHANNEL COUNTER“).

详细介绍

销售:钟    

M0ODEL2140计数器、M0ODEL2140计数器、

This extraordinarily versatile dual-channel Counter Meter can perform a wide variety of functions, particularly when it is equipped with the "R" OPTION ("EXTENDED DUAL-CHANNEL COUNTER").

Each of the following 2140 / 2140R functions is described separay below. General 2140 Specifications (applying to all modes of operation) are also given below.

  • DUAL-CHANNEL UP/DOWN TOTALIZING with independently scalable channels and presets
  • RATIO AND DRAW MEASUREMENT with arithmetic functions applicable to rate or total
  • TIME INTERVAL MEASUREMENT AND "STOPWATCH" OPERATION for periodic time measurement and one-time events
  • PHASE ANGLE AND DUTY CYCLE for offset in degrees and ON/OFF period in percent
  • PULSE-INPUT BATCHING with three relay outputs for automated batch control

In general, the 2140's two channels can accept PNP or NPN outputs from proximity switches and other pulse-generating industrial transducers; TTL or CMOS logic signals; magnetic pickup pulses down to 12 mV; contact closures; low-level outputs from all types of turbine flowmeters; or AC line inputs of up to 250 V-AC. The inverse period technique is used to calculate frequency or rate up to six places, and with an update as high as 25/s (see General Counter Meter Specifications).

Nine hysteresis pairs are jumper selectable for reliable triggering with different signal levels. Low-pass filtering for noise reduction and contact debounce times are selectable (see Specifications, below).

The 2140's six-digit display can show any value from -999,999 to 999,999 with programmable decimal point. Scaling allows direct readout in desired engineering units (e.g., gallons or cubic feet based on counts from a turbine flowmeter). The channel to be displayed is selected via a front-panel pushbutton.

The peak value of the input signal is automatically captured and may be displayed via front-panel push button or a control signal received at the rear connector (since the last meter reset).

The built-in isolated excitation supply can power proximity switches and other sensors, if required.

In addition to the "R" OPTION (discussed, where applicable, in the following sections), 2000 Series options applying to the Model 2140 Counter Meter include:

  • Isolated Relay Outputs
  • Isolated Analog Output (the 2140's ability to output an isolated 4-20 mA signal which tracks a total may be unique among totalizers)
  • RS232 or RS485 Interface
  • BCD Digital Interface
  • Low AC/DC Power

 

收藏该商铺