3KVA/50KV油浸式试验变压器
技术参数:
| 容量 | 高压电压(KV) | 高压电流(mA) | 低压输入 | 变比 | 温升℃ | |||
(KVA) | AC | DC | AC | DC | 电压(V) | 电流(A) | 高/仪 | 30分钟 | |
YD 1.5/50 | 1.5 | 50 | 70 | 30 | 15 | 200 | 7.5 | 500 | 10 |
YD 3/50 | 3 | 50 | 70 | 60 | 15 | 200 | 15 | 500 | 10 |
YD 5/50 | 5 | 50 | 70 | 100 | 15 | 200 | 25 | 500 | 10 |
YD 10/50 | 10 | 50 | 70 | 200 | 50 | 200 | 50 | 500 | 10 |
YD 20/50 | 20 | 50 | 70 | 400 | 100 | 400 | 50 | 500 | 10 |
YD 30/50 | 30 | 50 | 70 | 600 | 100 | 400 | 75 | 500 | 10 |
YD 40/50 | 40 | 50 | 70 | 800 | 105 | 400 | 100 | 500 | 10 |
YD 50/50 | 50 | 50 | 70 | 1000 | 100 | 400 | 125 | 500 | 10 |
YD 10/100 | 10 | 100 | 140 | 100 | 50 | 400 | 25 | 1000 | 10 |
YD 20/100 | 20 | 100 | 140 | 200 | 100 | 400 | 50 | 1000 | 10 |
YD 30/100 | 30 | 100 | 140 | 300 | 100 | 400 | 75 | 1000 | 10 |
YD 40/100 | 40 | 100 | 140 | 400 | 100 | 400 | 100 | 1000 | 10 |
YD 50/100 | 50 | 100 | 140 | 500 | 100 | 400 | 125 | 1000 | 10 |
YD 20/100 | 20 | 150 | 210 | 133 | 100 | 400 | 50 | 1500 | 10 |
YD 30/100 | 30 | 150 | 210 | 200 | 100 | 400 | 75 | 1500 | 10 |
YD 40/100 | 40 | 150 | 210 | 267 | 100 | 400 | 100 | 1500 | 10 |
YD 50/100 | 50 | 150 | 210 | 333 | 100 | 400 | 125 | 1500 | 10 |
YD 100/150 | 100 | 150 | 210 | 667 | 150 | 400 | 250 | 1500 | 10 |
3KVA/50KV油浸式试验变压器
操作实验办法:
1、 按上图接线,审查压力表批示外部气体压力能否一般(≥0.3MPA)
2、 做交流耐压时短路杆拔出孔J中,做直流走漏实验,存入短路杆。
3、 限流电阻设置装备摆设:工频耐压每伏0.3~1欧:直流每伏5~10欧,正常试 验可不必。
4、 撤除被试品线引线,套管及器身脏污肃清,多余时采纳屏障措施。
5、 预备任务和保险措施停当,空试一次设备。
6、 接上被试品,直流实验使用屏障线,以排除杂散走漏。
7、 合上电源,掌握箱(柜)电源指示绿灯亮。
8、 按下起动旋钮,起动批示灯亮。
9、 对于掌握箱,逆时针匀称加电,凝视电压抒发到额外电压值。
10、 延续规则耐压时间并凝视电流表批示。
11、 耐压时间到,凝视KV表,疾速匀称降零。
12、 做图2试验后用放电棒经电阻放电,而后直接接地放电。
13、 高压全体能够被充洪水位置逐个放电后,改观或者撤除高压引线,及所有引线至此一次实验停止。