| 注册| 产品展厅| 收藏该商铺

行业产品

当前位置:
广州尖分科学仪器有限公司>>戴安 Dionex>>Bio Columns>> CarboPac PA200 Carbohydrate Column

CarboPac PA200 Carbohydrate Column

返回列表页
  • CarboPac PA200 Carbohydrate Column
收藏
举报
参考价 面议
具体成交价以合同协议为准
  • 型号
  • 品牌
  • 厂商性质 代理商
  • 所在地 广州市
在线询价 收藏产品

更新时间:2016-10-27 15:58:27浏览次数:311

联系我们时请说明是化工仪器网上看到的信息,谢谢!

同类优质产品

更多产品

产品分类品牌分类

更多分类

产品简介

CarboPac PA200 Carbohydrate ColumnA variety of HPLC approaches are proposed for characterizing oligosaccharides, but many prove inadequate for separating complex mixtures and are limited by a lack of

详细介绍

Fast, pH-Stable Separation of Oligosaccharides

A variety of HPLC approaches are proposed for characterizing oligosaccharides, but many prove inadequate for separating complex mixtures and are limited by a lack of specificity and high limits of detection. Dionex has developed an improved HPLC technique for carbohydrate analysis based on anion-exchange chromatography coupled with pulsed amperometric detection. This technique provides high-resolution separations with sensitive and specific detection, without derivatization.

  • Sensitive, direct detection with no derivatization, using pulsed amperometric detection

  • Very high-efficiency separations

  • Separations based on size, charge, degree of branching, and linkage isomerism

  • Low flow rate saves on eluent consumption

  • Does not require derivatization

CarboPac® PA200 columns are packed with a hydrophobic, polymeric, pellicular anion-exchange resin stable over the range of pH 0–14. The unique pH-stability of the packing material allows the use of eluent compositions that are conducive to anodic oxidation of carbohydrates at gold electrodes.

CarboPac PA200 Column for High-Resolution Oligosaccharide Separations Specifications
DimensionsCarboPac® PA200 Analytical Column:
3 × 250 mm
CarboPac PA200 Guard Column:
3 × 50 mm
Maximum operating pressure4000 psi (27.9 MPa)
Temperature range6–60 °C  
Recommended operating temperature: controlled ambient
Typical operating conditions2700 psi at 0.5 mL/min (analytical and guard columns)
Recommended flow rate: 0.5 mL/min
phase compatibilitypH 0–14; * compatible with common organic solvents. 
Ionic form eluents: sodium acetate and sodium hydroxide only.
Resin composition5.5 µm-diameter ethylvinylbenzene/divinylbenzene substrate (55% cross-linked) agglomerated with 43 nm MicroBead® quaternary amine functionalized latex (6% crosslinked)
Anion-exchange capacityApproximay 35 µeq/column (3 × 250 mm analytical column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic
 

收藏该商铺