Human Anti-Cardiolipin IgG ELISA kit 心磷脂IgG检测试剂盒说明书

阅读:341      发布时间:2023-11-08
分享:

人抗心磷脂IgG检测试剂盒

Human Anti Cardiolipin IgG ELISA kit

cat#3300-170-CLG


Intended Use


Anti Cardiolipin IgG is an indirect enzyme immunoassay (ELISA) for thedetermination of IgG class autoantibodies against Cardiolipin in human serum orplasma. ADI’s Anti-Cardiolipin IgG ELISA KIT is intended for research use only,not for use in diagnostic procedures.

General Information


Anti-cardiolipin antibodies (aCL) can be considered as one of three groups ofanti-phospholipid antibodies, the others being VDRL and lupus anticoagulant(LAC). aCL and LAC antibodies appear to be closely related, or to recognizesimilar antigenic determinants. Of the anti-phospholipid antibodies, aCL areobserved most frequently and can be associated with a diverse set of clinicalmanifestations including neurological dysfunction, venous or arterial thrombosis,thrombocytopaenia and recurrent foetal loss5. Measuring aCL antibody levelsmay well be more useful than other anti-phospholipids because of these clinicalassociations6,7. The IgG isotype appears to provide the best correlation, IgM isalso found but IgA is more rare.


General Information


Anti-cardiolipin antibodies (aCL) can be considered as one of three groups ofanti-phospholipid antibodies, the others being VDRL and lupus anticoagulant(LAC). aCL and LAC antibodies appear to be closely related, or to recognizesimilar antigenic determinants. Of the anti-phospholipid antibodies, aCL areobserved most frequently and can be associated with a diverse set of clinicalmanifestations including neurological dysfunction, venous or arterial thrombosis,thrombocytopaenia and recurrent foetal loss5. Measuring aCL antibody levelsmay well be more useful than other anti-phospholipids because of these clinicalassociations6,7. The IgG isotype appears to provide the best correlation, IgM isalso found but IgA is more rare.


Measuring range


0 - 120 GPL-U/ml


Interferences:

No interference has been observed with haemolytic (up to 1000 mg/dl) or lipemic(up to 3 g/dl triglycerides) sera or plasma, or bilirubin (up to 40 mg/dl) containingsera or plasma. Nor have any interfering effects been observed with the use ofanticoagulants (Citrate, EDTA, Heparine). However for practical reasons it isrecommended that grossly hemolyzed or lipemic samples should be avoided.