产品简介

SOLAIR 3350E大流量空气微粒计数器 每立方米10分钟之内快速准确的采样,与具有0.3微米和0.5微米感应度的1立方英尺每分钟和2立方英尺每分钟的计数器相比,Solair3350和Solair5350便携式空气粒子计数器能够提供更快速的洁净室鉴定

详细介绍

SOLAIR 3350 / 5350

100 LPM
Airborne Particle Counters

With fast, reliable sampling of one cubic meter of air in only ten minutes, the SOLAIR 3350 and SOLAIR 5350 portable airborne particle counters offer faster cleanroom qualification than 1 and 2 CFM counters and at sensitivities of 0.3 and 0.5 microns, respectively. SOLAIRs incorporate our Extreme Life Laser Diode Technology sensor to produce the industry’s longest laser diode life of 20+ years MTTF (based on continuous 24/7 operation). The SOLAIR 3350 is the industry’s only 100 LPM 0.3 micron portable designed for continuous use.

SOLAIRs use the industry’s best UI (User Interface) to configure and operate the instrument. The intuitive ICON-driven screens and menus are easy to learn and use, which simplifies SOP writing, and support multiple languages.

SOLAIRs can store up to 3,000 records of particle count data from up to 8 particle channels and the configurable recipe database can store up to 50 recipes for sampling and reports. All data can be quickly and reliably transferred to a computer, a Facility Monitoring System or Building Automation System.

Secure data transfer (per 21 CFR Part 11) to a USB Flash Drive can be accomplished by using the Lighthouse Secure Data transfer feature and LMS Express or Express RT software. Flexible communication with these instruments is made possible by the integrated Ethernet, RS-485, USB and USB Flash Drive interfaces.

SOLAIRs are designed, manufactured and calibrated to ISO 21501-4 to ensure particle counting accuracy.

Designed and built by Lighthouse Worldwide Solutions, a name you can trust.

Solair 3350 / 5350 Datasheets
Letter Size – Lo Res               A4 Size – Lo Res

  • Features
  • Benefits
  • Applications
  • SOLAIR 3350: 0.3-25.0µm, 0.3µm @ 100 LPM
  • SOLAIR 5350: 0.5-25.0µm, 0.5µm @ 100 LPM
  • Samples 1 Cubic Meter in 10 Minutes @ 100 LPM
  • Simultaneous Display of up to 8 Particle Sizes
  • NOW with Advanced Sampling and Report Recipes and Improved TFT Touch Screen Display
  • 21 CFR Part 11 Compliant Secure Data Transfer via USB Flash Drive
  • Extreme Life Laser Diode Technology >20-year MTTF Laser Lifespan
  • Thermal Printer
  • Stainless Steel Construction
  • Designed for ISO 21501-4 Compliance: Unit-to-Unit Accuracy & Repeatability Assured
  • Multiple Communication Interfaces - USB, RS-485, Ethernet and USB Flash Drive
  • 5.7-inch Color TFT Touch Screen Display
  • 3000-record Data Storage Memory
  • 50-record Configurable Recipe Database
  • User-Definable Printouts
  • Open Architecture Connectivity with OPC Server
  • Report Wizard for Cleanroom Pass/Fail Reports: FS-209E, ISO-14644-1 or EU GMP Annex 1
  • Reduced Sample Time of 1 Cubic Meter in 10 minutes
  • User Friendly Interface with Multiple Languages
  • International Support
  • 2 year Warranty
  • Easy Integration to External Systems with OPC Server
  • Cleanroom Monitoring
  • Facility Certification Testing
  • Trend Analysis
  • Tool and Equipment Testing
  • Compressed Gas Monitoring (with High Pressure Controller)

Specifications

 
3350
5350
Size Range: 0.3 - 25.0μm 0.5 - 25.0μm
Standard Channel Sizes: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0μm 0.5, 0.7, 1.0, 3.0, 5.0, 10.0μm
Optional Channel Sizes: 0.3, 0.5, 1.0, 5.0, 10.0, 25.0μm 0.5, 1.0, 3.0, 5.0, 10.0, 25.0μm
     
Flow Rate: 100.0 LPM (3.53 CFM)
Counting Efficiency: 3350, 50% @ 0.3μm; 100% @ sizes > 0.45μm; 5350, 50% @ 0.5μm; 100% @ sizes > 0.75μm Per JIS B 9921 and ISO 21501-4
Light Source: Extreme Life Laser Diode Technology with >20-year Mean Time To Failure (MTTF)
Zero Count Level:  
Concentration Limits: 400,000 Particles/ft3 (14,120,000/M3) @10% Coincidence Loss, Suitable for ISO classes 1 through 8 Cleanrooms
Calibration: Meets ISO 21501-4 Calibration using NIST Traceable PSL Spheres, DMA and Condensation Particle Counter
Count Modes: Automatic, Manual, Beep, Concentration, Cumulative/Differential and Real Time (with Let or LMS Express RT)
Data Storage: 3,000 Sample Records (Rotating Buffer), which includes particle and environmental data with locations and times
Communication Modes: USB; Ethernet; RS-485; Secure Data Transfer to and Storage on USB Flash Drive
Supporting Software: LMS XChange, LMS Express and Express RT; LMS Standard; LMS Pharma; CREWin
Environmental Sensors: Optional (up to 4): Temperature/Relative Humidity, Air Velocity, Differential Pressure or others
Touch Screen Display: 5.7-inch (14.47 cm) Color TFT Touch Screen Display
Location Labels: Up to 400, based on Location Label Length
Printer: Built-in Thermal Printer (non-printer model available)
Reports: Pass/Fail Report Wizard for ISO-14644-1, EU GMP Annex 1 and FS-209 Report Formats
Alarm: Integrated Alarm Buzzer and External Alarm Connector. Alarms on Counts, Low Battery, Sensor Failure
Enclosure: Stainless Steel
Sample Output: Internally filtered to HEPA standards (>99.997% @ 0.3μm)
Vacuum Source: Internal Closed-loop Controlled Pump: allows the use of 3/8” ID Sample Tubing of up to 12 Meters (40 feet) @ 100 LPM
Power: 100-250 VAC, 47-63 Hz
Battery: Li-Ion, Removable & Rechargeable; Typical Battery Operation ~4 hours*; Tyical Recharge Time ~4 hours
Dimensions: 14.65” (l) x 8” (w) x 10.4” (h) [37 x 20 x 26 cm]
Weight: With Battery: 26 lbs (11.8 kg) Without Battery: 23 lbs (10.43 kg)
Languages: English, Français, Deutsch, Italiano, Español, Chinese (Simplified)

Conditions

Operating: 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing
Storage: 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing

Accessories

Included: Operating Manual on CD; Isokinetic Sample Probe with Tripod and Tubing; Purge Filter; Power Cable and Spare Fuse; LMS XChange and Express Software; Printer; Printer Paper
Optional: Wireless Network Adapter; Removable Rechargeable Li-Ion Battery; Carrying Case with Wheels; Temperature / Relative Humidity Probe; Differential Pressure Probe; Inligent Filter Scanning Probe; Air Velocity Probe; Spare Removable Rechargeable Li-Ion Battery; External Battery Charger; LMS Express RT Software; LMS Pharma Edition Software; LMS Standard Software; Validation Documentation; Printed Operating Manual; Cleanroom Cart