您好, 欢迎来到化工仪器网

| 注册| 产品展厅| 收藏该商铺

020-38216008

products

目录:广州市自力色谱科仪有限公司>> G1315A安捷伦1100系列DAD检测器G1315A

安捷伦1100系列DAD检测器G1315A
  • 安捷伦1100系列DAD检测器G1315A
  • 安捷伦1100系列DAD检测器G1315A
  • 安捷伦1100系列DAD检测器G1315A
  • 安捷伦1100系列DAD检测器G1315A
  • 安捷伦1100系列DAD检测器G1315A
参考价 面议
具体成交价以合同协议为准
参考价 面议
具体成交价以合同协议为准
  • 品牌 Agilent/安捷伦
  • 型号 G1315A
  • 厂商性质 经销商
  • 所在地 广州市
属性

>

更新时间:2024-06-13 10:28:00浏览次数:3020评价

联系我们时请说明是化工仪器网上看到的信息,谢谢!

同类优质产品

更多产品
二手安捷伦1100系列DAD检测器G1315A
完好无损,经过全面检测,能即时使用。

Agilent 1100 Series G1315A DAD Diode Array Detector For HPLC Lab

This listing is for an Agilent 1100 Series DAD Diode Array Detector G1315A

The unit is in good shape.

Fully tested ready for installation at your location.

Comes as shown with power cord.

You can add spectral acquisition to your HPLC analyses with the HP 1100 Series diode array detector. Verify separation quality with peak purity, multiple signals and spectral libraries - interactively or automatically in the same run as your analytical quantification. Extended wavelength range from 190 to 950 nm with highest sensitivity or spectral resolution with programmable slit. And holmium oxide wavelength verification for GLP compliance. The temperature management system ensures optimum baseline stability-even under rough ambient conditions.

Two lamps in the HP 1100 Series diode-array detector ensure the highest light output from 190 to 950 nm, for the lowest detection limits over the entire wavelength range. The use of 1,024 diodes and an optical slit programmable from 1 to 16 nm ensures the best possible spectral bandwidth.

Both the VWD and diode array detectors use a holmium oxide filter for automated wavelength verification and for tracking the detector's performance characteristics. They also employ a new design that allows front access for the exchange of flow cells and pre-aligned lamps.

 

Features:

  • Access the spectral domain with superior 3D optics-simultaneous illumination using combined deuterium and tungsten lamps for highest intensity and lowest detection limit from 190 to 950 nm, 1024 diodes and 1-nm slit for highest spectral resolution.
  • Programmable slit helps you explore the spectral landscape for faster sample characterization-focus on fine bands with narrow setting, or if higher sensitivity is required open up the programmable slit for more light throughput. A broad slit ensures lowest baseline noise and highest chromatographic signal-to-noise. Store and report slit settings, from 1 - 16 nm, together with your raw data for GLP traceability.
  • Spectral storage and flexible viewing -easily overlaid spectra within a run or between runs.
  • Verify wavelength accuracy for GLP compliance-automatic holmium oxide filter (which can be set at the beginning of your chromatography) verifies that your wavelength is indeed what the setpoint says it is.

会员登录

请输入账号

请输入密码

=

请输验证码

收藏该商铺

标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

您的留言已提交成功!我们将在第一时间回复您~
在线留言

会员登录

请输入账号

请输入密码

=

请输验证码

收藏该商铺

该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:
热线电话 在线询价