电磁流量计Promag 55H系列德国E+H
- 公司名称 上海爱丁机械设备有限公司
- 品牌
- 型号
- 产地
- 厂商性质 代理商
- 更新时间 2016/8/25 20:04:49
- 访问次数 587
联系我们时请说明是化工仪器网上看到的信息,谢谢!
E+H雷达物位计,E+H导波雷达物位计,E+H机电式物位计,E+H超声波物位计,E+H电容式物位计,E+H静压液位计,E+H差压液位计,E+H放射线物位计,E+H音叉料位开关,E+H电导料位开关,E+H浮子开关,E+H阻旋料位开关,E+H微波限位开关,E+H控制单元,E+H调试工具,E+H伺服 / 浮子罐
咨询俞
电磁流量计Promag 55H系列德国E+H
Your benefits
Promag measuring devices offer you cost-effective flow measurement with a high degree of accuracy for a wide range of process conditions.
电磁流量计Promag 55H系列德国E+H
The uniform Proline transmitter concept comprises:
-
Modular device and operating concept resulting in a higher degree of efficiency
-
Software options for: electrode cleaning, advanced diagnostics, calculation of mass flow and solids content
-
Uniform operating concept
-
The tried-and-tested Promag sensors offer:
-
Excellent accuracy and repeatability
-
Optimum operational safety due to advanced, permanent self-diagnosis
-
No pressure loss
-
Not sensitive to vibrations
-
Simple installation and commissioning
应用领域
Electromagnetic flowmeter for bidirectional measurement of liquids with a minimum conductivity of ≥ 5 μS/cm - in particular fluids with solids, inhomogeneous or tend to build-up, for example:
-
Fruit mashes, fruit concentrates and final products (salad dressings, soups with vegetable pieces)
-
Beverages, e.g. fruit juice, beer, wine
-
Dairy products, fruit juice mixes
-
Saline solutions
-
Acid, alkalis, etc.
-
Chemically inhomogeneous fluids (e.g. additives)
-
Flow measurement up to 4700 dm3/min (1250 gal/min)
-
Fluid temperature up to +150 °C (+302 °F)
-
Process pressures up to 40 bar (580 psi)
-
Fitting lengths as per DVGW/ISO
-
CIP/SIP cleaning
-
Stainless steel housing
Approvals in food sector/hygiene sector:
-
3A approval, EHEDG-tested, conform to FDA, USP Class VI
Application-specific lining material:
- PFA
Approvals for hazardous area:
-
ATEX, FM, CSA
Connection to process control system:
-
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus
-
-
测量原理 Electromagnetic Product headline Volume flow meter for measurement of demanding conductive fluids in hygienic / food / process applications Sensor features S-DAT, T-DAT, F-CHIP
Quick Set-Up
ECC
3 totalizers
Bi-directional totalizer
Pulsating flow
Density function
Massflow (using density input)
Diagnostics
3A authorization and EHEDG-testedNominal diameter range DN 2...150
1/12"...6"Max. measured error ±0.25% Measuring range 0...600 m3/h Max. process pressure PN16...40 Medium temperature range -20...+150°C
(-4...+302°F)Degree of protection IP 67 (NEMA 4x) Display/Operation Four line display with backlit
Touch controlOutputs 4...20 mA
Pulse / frequency(active/passive)
Relais
StatusInputs Status
Current inputDigital communication HART
PROFIBUS PA
FOUNDATION FieldbusHazardous area approvals ATEX
FM
CSA