| 注册| 产品展厅| 收藏该商铺

行业产品

当前位置:
北京恒泰正宇科技有限公司>>美国进口蓄电池>>MAX蓄电池>> PS-12260NB法国power sonic蓄电池PS-12260NB 12V26AH

法国power sonic蓄电池PS-12260NB 12V26AH

返回列表页
  • 法国power sonic蓄电池PS-12260NB 12V26AH
  • 法国power sonic蓄电池PS-12260NB 12V26AH
  • 法国power sonic蓄电池PS-12260NB 12V26AH
  • 法国power sonic蓄电池PS-12260NB 12V26AH
  • 法国power sonic蓄电池PS-12260NB 12V26AH
收藏
举报
参考价 面议
具体成交价以合同协议为准
  • 型号 PS-12260NB
  • 品牌 其他品牌
  • 厂商性质 代理商
  • 所在地 北京市
在线询价 收藏产品

更新时间:2020-11-02 15:04:23浏览次数:457

联系我们时请说明是化工仪器网上看到的信息,谢谢!

同类优质产品

更多产品

产品简介

供货周期 现货
法国power sonic蓄电池PS-12260NB 12V26AH
我司所售的蓄电池保证是原厂原装产品,,签订合同,
38AH以上出现非人为质量问题三年内免费更换同等型号的全新电池,请广大客户放心采购!

详细介绍

法国power sonic蓄电池PS-12260NB 12V26AH

法国power sonic蓄电池PS-12260NB 12V26AH

 

 

  Power-Sonic一直是主导力量在电池业务超过46年。由于我们的承诺我们公司蓬勃发展提供高质量的成本有效的电池,支持水平的服务是的。

  

  我们骄傲我们的灵活性和能力迅速采取行动为市场带来新的行业产品。我们很自豪持有ISO 9001认证覆盖我们的组织的各个方面。

How long will my battery last?
The lifespan of a battery will vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

How to connect a battery in Series?
The positive terminal of the first battery is connected to the negative terminal of the second battery, the positive terminal of the second is connected to the negative of the third, etc. The voltage of the assembled battery is the sum of the battery voltages of the individual batteries. So the batteries are connected: + to - to + to - to + to -, etc. The capacity of the battery is unchanged.

 

此种供电系统的缺点:
此供电系统要求直流元器件;对器件灭弧要求高;由于电压高,无过零点,对安全性要求高。
八、高压直流供电系统解决方案三
高电压直流供电系统方案三与方案二供电系统是类似的,所不同的是,方案三供电系统增加升压电路,将直流输出电压提高到400V(此种类似的供电系统在移动公司有实验点,直流电压350V)。是针对专门的高压服务器电源,目前此服务器尚在研制之中,由于系统输出电压高,对目前大量在使用的服务器有些是不可用的,但由于某些优点突出,可能成为未来的一种发展的趋势。系统图见图9。


此方案供电系统的优点:
模块化供电,电池直接连接负载,母线电源不间断;电源效率高,较节能;输出为直流无率因数与谐波问题,具备大负载能力;供电电缆细,节省成本与空间。
此方案供电系统的缺点:
故障的安装拆除易造成拉弧;对安全的要求高,器件的要求也高。
结论
电信技术的迅速发展推动了电源设备技术的进步,高电压直流供电系统方案二与方案三因为其可靠性高,效率高,特别适用于设备功率较大的场合的IDC机房供电。方案二适合于目前的服务器,也是目前IDC机房供电的改造相对较适合的方案,方案三可能是一种IDC机房设备供电的发展趋势。IDC机房供电系统到底是什么,还值得深入探讨与研究,终总会找到一种适合的方案。

How to connect a battery in Parallel?
The positive terminal of the first battery is connected to the positive terminal of the second battery, the positive terminal of the second is connected to the positive of the third, etc. and The negative terminal of the first battery is connected to the negative terminal of the second battery, the negative terminal of the second is connected to the negative of the third, etc. So the batteries are connected: + to + to + and - to - to -. In this configuration, the capacity is the sum of the capacities of the individual batteries and voltage is unchanged. For example, if you take 5 6V 10AH batteries and connect the batteries in series, you would end up with a battery array that is 30 Volts and 10AH. If you connect the batteries in parallel, you would end up with a battery array that is 6 Volts and 50AH. By the way, this is how ordinary auto batteries are made. 6 2volt cells are put in series to give 12v battery and the 6 cells are just enclosed in one case. Many ni-cad batteries are done the same way.

PS and PSH-Series General Purpose used for :

  • Emergency Lighting
  • Burglar/Fire Alarms
  • Data Centers
  • Solar and Alternative Energy
  • Portable Communications
  • Wind Turbines
  • Robotics
  • Remote Monitoring
  • Portable Video Equipment
  • Portable Lighting
  • Photographic Equipment
  • Scientific Instruments
  • Test and Measuring Equipment
  • and much more...

PG-Long Life and PHR-High Rate Series used for :

  • Communication & Telecom Systems
  • UPS - Uninteruptible Power Supplies
  • Power Station Applications
  • Remote Monitoring
  • Remote Area Power Generation
  • Remote Access Devices
  • and much more...

 

型号

标称电压

额定容量

尺寸/重量

V

20hr

总高

公斤

 

PS-1272

12

7.2

151

65

94

98

2.40

PS-1280

12

8

151

65

94.5

100

2.5

PSH-1280FR

12

8.5

151

65

94

98

2.72

PS-1282L

12

9

196

56

118

118

3.13

PS-1282S

12

9

98

112

118

118

3.13

PS-1290

12

9

151

65

94

98

2.72

PS-12100

12

12.0

151

102

94

98

3.69

PS-12100H

12

10.5

151

65

112

118

3.28

PSH-12100FR

12

10.5

151

65

111

117

3.18

PS-12120

12

12.0

151

98

94

100

3.59

PS-12120L

12

12.0

215

70

146

146

3.99

PS-12140

12

14.0

151

98

94

100

4.09

Can I take a wheelchair, scooter or other equipment that is powered by a sealed AGM or Gel battery on a airplane or cruise ship?
Yes. There should be no problem, the battery is considered non-spillable, non-hazardous, since it is a absorbed glass mat design. These sealed lead acid valve regulated (VRLA) batteries are classified as "Battery, wet non-spillable, not subject to regulations" by DOT and IMO. By IATA they are classified as "Not restricted for air transport" and they are in compliance with IATA/ICAO special provision A67. For the gelled electrolyte batteries, they are classified as "Battery, wet, filled with acid, UN2794, Class 8". They can be legally shipped via air with special packaging etc.

How do I Jump Start my Battery using booster cables?
WARNING-BATTERIES PRODUCE EXPLOSIVE GASES. These instructions are designed to minimize the explosion hazard. Keep sparks, flames and cigarettes away from batteries at all times. Both batteries should be of the same voltage (6, 12, etc.).

SAFE BOOSTER CABLE OPERATION When jump starting, always wear proper eye protection and never lean over the battery. Do not jump start a damaged battery; inspect both batteries before connecting booster cables. Be sure vent caps are tight and level. Be sure that the vehicles are not touching and that both ignition switches are in the "OFF" position. Turn off all electrical equipment (radio, defroster, windshield wipers, lights, etc.)

 

公司一贯坚持“质量*,用户至上,优质服务,信守合同”的宗旨,凭借着高质量的产品,良好的信誉,优质的服务,产品全国近三十多个省、市、自治区公司与多家零售商和代理商建立了长期稳定的合作关系,公司实力雄厚,重信用、守合同、保证产品质量,以多品种经营特色和薄利多销的原则,赢得了广大客户的信任

 前言:
数据中心机房建设要求非常高,国标规范都有哪些要求呢?今天一起来学习一下吧!
正文:
工程中的数据中心机房建设是保证计算机网络设备和各级劳动保障系统正常运转的关键。现在的计算机设备对运行环境要求较高。因此,必须按照一定的标准规范,科学地设计机房。
一、机房建设需要执行的标准
主机房建设工程必须遵循国家机房设计标准规范的要求。
二、场地要求
计算机机房在多层建筑或高层建筑物内一般应设于第二、三层,水源充足,电力稳定可靠,应远离产生粉尘、油烟、有害气体以及贮存具有腐蚀性、易燃、易爆物品的仓库等;远离强震源和强噪声源;避开强电磁场*(如广播发射台、雷达站、高压线等),此外还要具备下列条件:
1、对环境的温度、湿度要求;
2、对空气的洁净度、新鲜度和流动速度要求;
3、对电源、电压、频率和稳定性、后备时间要求;
4、对照明的照度、眩光、均匀度、稳定性、显色性、光效要求及产生有害电磁波的限制及应急照明要求;
5、对各房间楼板荷载要求;
主机房:5.0-7.5KN/m2;配线间及网络设备间:5.0-7.5KN/m2;电源室:要根据蓄电池摆放形式确定,约为8.0-12KN/m2;一般工作间:2.5KN/m2.
6、对消防、电磁*、安全保密还必须满足机房工作人员的卫生环境要求和对外的形象要求。
三、机房组成及划分
1、功能划分数据中心机房组成应按计算机运行特点及设备具体要求确定,机房面积可根据计算机设备数量或占地面积进行估算。
一般机房设计,除考虑主机房用房外,还要考虑到配置各种辅助用房,具体包括以下几类:(1)辅助工作间类:如网管监控、终端数据录入、备份介质存储等。(2)硬件维护、软件调试、培训教室、办公室等工作用房。(3)配套动力用房:包括配电间、发电机房等。(4)辅助用房:厕所、楼梯、电梯等用房。
2、结构与装修数据中心机房在结构上应设独立的出入口,当与其它部门共用出入口时,应避免人流、物流交****;宜设门厅、休息室和值班室。人员出入主机和基本工作间应更衣换鞋。机房与其他建筑物合建时,应单独设防火分区。计算机房安全出口不应少于两个,并尽可能设于机房两端。机房装修包括地板、吊顶、墙壁装修以及隔断、防火金属门建设;机房装修要体现机房区域的特点,从内部看,要重点体现高科技的工作环境、严谨的科学气氛、简洁大方的装修线条、庄重典雅的装修色彩、以及以人为本的环保装修理念。机房装修要严格按照国家相应的标准规范执行。
3、供配电系统根据运行负荷的重要性程度确定供电电源等级。机房电气系统包括机房区的动力、照明、监控、通讯、维护等用电系统,按负荷性质分为计算机设备负荷和辅助设备负荷,计算机设备和动力设备应分开供电。供配电系统的组成包括配电柜、动力线缆、线槽及插座、接地防雷、照明箱及灯具、应急灯、照明线管。应独立设置计算机设备配电柜和辅助设备配电柜。
雷击一般分为直击雷和感应雷,在机房防雷系统设计中主要避免感应雷,在配电柜进线侧面的三条火线、一条零线分别并联一个过电压保护装置。
4、机房空调系统根据数据中心机房环境及设计规范要求,主机房和基本工作间,均应设置空气调节系统。其组成包括精密空调、通风管路、新风系统。流送回风所采用下送上回、上送下回、上送侧回等方式。新风宜采用经温湿度、洁净度预处理后的新风,与回风混合后送入机房。
5、机房消防系统机房消防系统由烟感、温感等消防报警系统及自动灭火系统组成。根据《电子计算机机房设计规范》(GB50174-93),计算机主机房应设置气体消防灭火系统。一般工作间、辅助间可采用水消防措施。同时,机房应设置火灾自动报警装置和应急广播。
6、机房环境监控系统机房环境监控系统是对机房中的空调设备、UPS设备、配电柜、空调水管有无漏水、机房环境的温湿度等环境参数进行集中监测管理的系统,是机房管理人员实现机房科学管理的重要手段。其组成包括空调系统监控、UPS系统监控、配电系统监控、漏水监测系统、温湿度监测系统。一套好的机房环境监控系统是机房硬件环境系统建设的有利补充,对保障计算机设备正常运行十分必要。
7、机房安全防范系统机房安全防范系统是保障机房安全的重要措施。它对机房内的重点区域进行实时图像监视和录像,对出入口实施门禁控制管理和考勤管理,对有可能发生入侵的场所实施报警管理。它由图像监控系统,门禁系统,防盗报警系统等子系统构成。各子系统之间实行一定的联动管理控制,以实现更优化的安全防范控制。
8、机房综合布线系统机房综合布线系统是架构在机房内部网络高速路。它连接着机房内部的众多的网络设备,并支持语音、图像、数据等传输。综合布线系统由水平子系统、垂直子系统、管理子系统、设备间子系统和工作区子系统构成。机房内的综合布线主要为水平布线。但IDC机房中也多采用多模光纤作为数据主干。目前的综合布线系统多采用超五类或六类系统。按材质又可分为屏蔽系统和非屏蔽系统。
总之,机房建设是一个系统的工程。在设计中要切实做到从工作需要出发,以人为本,满足功能需要,为设备提供一个安全运行的空间,兼顾美观实用,为从事计算机操作的工作人员创造良好的工作环境,为金保工程的顺利开展打下一个坚实的基础。

由于网页资源有限,具体电池型号、参数、价格咨询请致电。另外我们还为客户提供技术咨询服务,说出您的负载、延时时间等,我们会有专业的工程师为您提供ups电源、电池解决方案,让您真正的后顾无忧!

收藏该商铺

登录 后再收藏

提示

您的留言已提交成功!我们将在第一时间回复您~
二维码 意见反馈
在线留言